R32 Split ATW Heat Pump

R32 Split DC Inverter Air to Water Heat Pump for Europe

The heat pump is developed for house heating / cooling and domestic hot water, which adopts full DC inverter technology and R32 refrigerant to attain A+++ energy label.

  • Refrigerant: R32 (low GWP, non-ozone-depleting)

  • Capacity Range: 6 kW, 8 kW, 10 kW, 12 kW, 14 kW, 16 kW

  • Functions: Heating, Cooling & Domestic Hot Water; Two-Zone Independent Control

  • Efficiency: ErP A+++ @ 35 °C flow (TÜV-tested)

  • Controller: LCD Touchscreen + Free Wi-Fi App

  • Ambient Range: –25 °C ~ +43 °C

  • Max Water Outlet: Up to 65 °C (with electric heater backup)

HONWO-R32 Split ATW Features

Key Features:

ODP-Ozone Depletion Potential

Full DC Inverter & R32 Refrigerant

All major components—compressor, fan, and pump—use variable-speed DC inverters for rapid load matching, yielding COP up to 5.95 in EVI variants and stable performance in extreme temperatures. R32’s higher volumetric cooling capacity makes it ~87 % more efficient per unit volume than R290.

Superior Efficiency & Wide Operating Range

ErP A+++ @ 35 °C guarantees up to 30 % lower energy consumption versus A+ systems. Reliable heating at –25 °C ambient and domestic hot water up to 60 °C without backup heating.

LCD Controller

Quiet, Smart Control

Operates as low as 36 dB(A) @ 3 m for whisper-quiet comfort. The LCD touchscreen with Wi-Fi app supports scheduling, remote monitoring, and over-the-air updates.

R32 Split ATW Heat Pump schematic

Flexible, Future-Ready Design

Modular split design allows indoor placement of hydraulic components for retrofit or new-build projects. Compatible with solar thermal or gas boiler integration.

Smart Control & Quiet Operation

LCD touchscreen plus app control enables scheduling, remote diagnostics, and firmware updates. Sound levels down to 36 dB(A) at 3 m make it one of the quietest in its class.

SG Ready

SG-Ready for Smart-Grid Integration

Equipped with the industry-standard SG-Ready interface, this heat pump can receive external load-management signals—such as time-of-use price cues or grid-frequency notifications—to automatically adjust its runtime and maximize self-consumption of onsite renewables (e.g. PV) or participate in demand-response programs. This ensures you get the lowest operating costs, helps stabilize the public grid during peak periods, and makes your HVAC system “future-proof” as Europe’s energy networks evolve.

  • Grid-Friendly Demand-Response: Temporarily shed or shift heating to off-peak times at the grid operator’s signal, reducing strain on the network and earning potential tariff rebates.

  • PV-Smart Operation: When paired with a solar inverter or smart energy manager, the SG-Ready interface lets the heat pump soak up excess PV generation, storing solar energy as heat rather than exporting at low feed-in tariffs.

  • Standardized BWP Certification: Conforms to the German Heat Pump Association’s SG-Ready specification, guaranteeing compatibility across all major European smart-grid platforms.

By combining R32’s low GWP and high COP with SG-Ready intelligence, you gain a truly low-carbon, low-cost heating solution optimized for tomorrow’s energy systems.

Application Scenarios

  • Commercial Installations: Projects requiring precise dual-zone control for offices, hotels, or retail spaces.

  • Residential Complexes: Centralized heating, cooling, and DHW in multi-unit buildings.

  • Extreme Climates: Reliable performance even at –25 °C, ideal for cold-climate projects.

Trust Signals & Support

  • Certifications: CE, ErP A+++, TÜV SÜD tested

  • Warranty: 3-year compressor & heat exchanger; 2-year parts

  • Service Network: Authorized partners across Europe and global after-sales support

  • Case Study: Achieved 40 % energy savings vs. traditional boilers in a Spanish hotel retrofit

Model 6kW 8kW 10kW 12kW 14kW 16kW 12kW 14kW 16kW 18kW 20kW 22kW
Power supply 220 – 240V~, 1Ph, 50Hz 380 – 415V~, 3Ph, 50Hz
Heating A7W35 Heating capacity kW 6.80 8.40 10.00 12.00 14.10 16.00 12.00 14.10 16.00 18.00 20.00 21.70
Power input kW 1.42 1.73 2.24 2.48 3.07 3.60 2.48 3.07 3.60 3.73 4.21 4.84
COP 4.80 4.85 4.47 4.84 4.60 4.44 4.84 4.60 4.44 4.83 4.75 4.48
Heating A7W55 Heating capacity kW 5.50 8.00 9.30 12.00 14.00 16.00 12.00 14.00 16.00 18.00 20.00 21.60
Power input kW 1.93 2.68 3.31 4.43 4.98 5.82 4.43 4.98 5.82 5.86 6.54 7.08
COP 2.85 2.98 2.81 2.71 2.81 2.75 2.71 2.81 2.75 3.07 3.06 3.05
Cooling A35W7 Cooling capacity kW 5.00 6.00 7.00 11.00 11.50 12.50 11.00 11.50 12.50 13.50 14.50 14.70
Power input kW 1.67 2.03 2.43 4.09 4.51 5.10 4.09 4.51 5.10 4.74 5.18 5.46
EER 3.00 2.95 2.88 2.69 2.55 2.45 2.69 2.55 2.45 2.85 2.80 2.71
Seasonal space heating
energy efficiency class
(Water outlet at 35°C) A+++
(Water outlet at 55°C) A++
Maximum over-current protection A 14 15 16 22 26 29 22 26 29 31 32 35
Running ambient temperarure range ºC -25~43
Compressor Type DC inverter, twin-rotary
Fan Motor Type Brushless DC motor
Quantity 1 1 1 1 1 1 1 1 1 2 2 2
Air Flow m3/h 3,900 4,500 4,500 5,200 5,200 5,200 5,200 5,200 5,200 6,400 7,100 7,800
Air-side heat-exchanger Type Hydrophilic aluminum & Inner groove copper tube
Refrigerant Type R32
Charged volume g 1450 1450 1450 1840 1840 1840 1840 1840 1840 2950 2950 2950
Throttling type Electronic expansion valve
Water-side heat-exchanger Plate
Expansion tank Volume L 5 5 5 5 5 5 5 5 5 5 5 5
Safety valve MPa 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
Water pump Type DC,Shielded
Max. head m 9 9 9 9 9 9 9 9 9 9 9 9
Rated Water Flow m3/h 1.170 1.445 1.720 2.064 2.425 2.752 2.064 2.425 2.752 3.096 3.440 3.750
Safety valve MPa 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30 0.30
Water flow switch m3/h 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.36 0.36
Entering/leaving water pipes size G5/4″BSP
Backup electric heater Standard 3kW 6kW
Refrigerant pipes size Liquid/Gas pipe mm Φ9.52/Φ15.88 Φ9.52/Φ19.05
Sound power level (Indoor Unit) dB(A) 43 44 45 47 48 49 47 48 49 48 48 49
Sound power level (Outdoor Unit) dB(A) 58 59 61 64 65 68 64 65 68 68 69 71
Outdoor Unit Dimensions
(W×H×D)
Net mm 1040*850*450 938*1369*368
Packing mm 1150*983*527 1080*1518*470
Indoor Unit Dimensions
(W×H×D)
Net mm 290*470*790
Packing mm 370*550*895
Outdoor Unit Weight Net/Gross kg 70.3/82.3 87.0/99.0 87.7/99.6 96/108.0
Indoor Unit Weight Net/Gross kg 45.8/49.7 46.9/50.8 48.5/52.5
Notes:
1. The specification may be changed for product improvement, please refer to the nameplate of product.
2. Seasonal space heating energy efficiency class is tested in average climate conditions.
3. Relevant EU standards and legislation: EN14511, EN50564, EN14825, EN12102, (EU) No 811:2013, (EU) No 813:2013, QJ 2014/C 207/02:2014.

Why

Why Choose Honwo Heat Pump

01
Compliance Standards

We have standards from the United States, Europe, and Australia.

02
Factory Price

We have our own factory and offer the most direct factory prices.

03
Own R&D Team

We have a highly educated R&D team dedicated to the research and development of various HVAC products

04
CNAS & ETL Labs

We have four CNAS laboratories certified by ETL, and our products undergo strict quality control.

05
Complete Certification

The product complies with certifications such as CE, LVD, EMS, ErP, ETL, Keymark, SG Ready, etc.

06
Automatic Production Line

Our production process is highly automated, reducing manual errors.

news

News

Sample Project: Village project in Tianjin QTY: 395set Capacity: 5530kw
Sample Project: Athletes' Dormitory of Beijing Winter Olympic Games.
As a high quality HVAC Maker, HONWO has been following the American, European and Australian standards to ...

Contact

Contact HONWO

Get in Touch